- 商家货号:E16006US
The circuit analyzer is a special test device designed for AC low-voltage distribution line quick fault location. With simple operation, accurate measurement and other features, it can detect multiple problems on a line, such as causing to electric shock, electrical fire, abnormal operation of equipment, etc.
Features:
TRMS measuring AC voltage.
Artificial load 12A, 15A, 20A measuring line drop.
Measuring phase voltage, neutral line(zero line), voltage to earth, peak voltage, frequency.
Measuring phase(live line), neutral line(zero line), earth line conductor impedance.
Identifying 3-wire socket connection mode(zero for left and live for right, having earth line or not).
Test the reliability of residual current device(RCD) and response action time.
Test the reliability of GFCI action and response action time.
Backlight function and data hold function.
Specifications:
Line Voltage: 85.0~265.0V: 0.1V ±(1.0%+0.2V)
Peak voltage: 121.0~374.0V: 0.1V ±(1.0%+0.2V)
Frequency: 45.0~65.0Hz: 0.1Hz ±(1.0%+0.2Hz)
Voltage Drop: 0.1%~99.9%: 0.1% ±(2.5%+0.2%)
Voltage Loaded: 10.0~265.0V: 0.1V ±(2.5%+0.2V)
Voltage to Earth of Zero Line: 0.0~10.0V: 0.1V ±(2.5%+0.2%)
Impedance for Live Line, Zero Line and Earth Line: 0.00~3.00Ω: 0.01Ω ±(2.5%+0.02Ω)
RCD Triggering Time: 1ms~6.500s: 1ms ±(1.0%+2ms)
RCD Triggering Current: 30mA~37mA: 0.1mA ±(1.0%+0.2mA)
GFCI Triggering Timer: 1ms~6.500s: 1ms ±(1.0%+2ms)
GFCI Triggering Current: 6mA~9mA: 0.1mA ±(1.0%+0.2mA)
Plug Type: EU / US (Optional)
Display: LCD
Overload: "OL" or ">"
Auto Power-off: 30 minutes
Humidity: <80%RH (0~50℃)
Storage Temperature: 0~50℃, <80%RH
Power Supply: 6 * 1.5V AAA battery (NOT included)
Item Size: 194 * 78 * 37mm / 7.64 * 3.07 * 1.46in
Item Weight: 260g / 9.17oz
Package Weight: 600g / 21.16oz
Package Size: 26.2 * 14.5 * 6cm / 10.31 * 5.71 * 2.36in
Packing List:
1 * Voltage Circuit Analyzer
1 * Power Cord
1 * Storage Pouch
1 * Manual(English)
Features:
TRMS measuring AC voltage.
Artificial load 12A, 15A, 20A measuring line drop.
Measuring phase voltage, neutral line(zero line), voltage to earth, peak voltage, frequency.
Measuring phase(live line), neutral line(zero line), earth line conductor impedance.
Identifying 3-wire socket connection mode(zero for left and live for right, having earth line or not).
Test the reliability of residual current device(RCD) and response action time.
Test the reliability of GFCI action and response action time.
Backlight function and data hold function.
Specifications:
Line Voltage: 85.0~265.0V: 0.1V ±(1.0%+0.2V)
Peak voltage: 121.0~374.0V: 0.1V ±(1.0%+0.2V)
Frequency: 45.0~65.0Hz: 0.1Hz ±(1.0%+0.2Hz)
Voltage Drop: 0.1%~99.9%: 0.1% ±(2.5%+0.2%)
Voltage Loaded: 10.0~265.0V: 0.1V ±(2.5%+0.2V)
Voltage to Earth of Zero Line: 0.0~10.0V: 0.1V ±(2.5%+0.2%)
Impedance for Live Line, Zero Line and Earth Line: 0.00~3.00Ω: 0.01Ω ±(2.5%+0.02Ω)
RCD Triggering Time: 1ms~6.500s: 1ms ±(1.0%+2ms)
RCD Triggering Current: 30mA~37mA: 0.1mA ±(1.0%+0.2mA)
GFCI Triggering Timer: 1ms~6.500s: 1ms ±(1.0%+2ms)
GFCI Triggering Current: 6mA~9mA: 0.1mA ±(1.0%+0.2mA)
Plug Type: EU / US (Optional)
Display: LCD
Overload: "OL" or ">"
Auto Power-off: 30 minutes
Humidity: <80%RH (0~50℃)
Storage Temperature: 0~50℃, <80%RH
Power Supply: 6 * 1.5V AAA battery (NOT included)
Item Size: 194 * 78 * 37mm / 7.64 * 3.07 * 1.46in
Item Weight: 260g / 9.17oz
Package Weight: 600g / 21.16oz
Package Size: 26.2 * 14.5 * 6cm / 10.31 * 5.71 * 2.36in
Packing List:
1 * Voltage Circuit Analyzer
1 * Power Cord
1 * Storage Pouch
1 * Manual(English)
商品评价
100%好评
共有0人参与评分评价商品